GOGLOBAL11
GOGLOBAL11 Go-Global Verbosity Level Adjustments
Question: Can I change the verbosity of the GGfW log file?
(for version 3.1, this can be performed right from the Cluster Manager)
Answer: (for version prior to 3.1)
Yes the following options are available;
Setting the Output Level
GO-Global offers six log output levels, as follows:
1: Errors
2: Events
3: Warnings
4: Diagnostic Messages
5: Trace Messages
6: Extended Trace Messages
To set the output level
1. Stop the GO-Global Application Publishing Service.
2. From the Registry Editor, expand the HKEY_LOCAL_MACHINE key.
3. Locate the AppServer key: [Software\\GraphOn\\Bridges\\1.0.0\\AppServer]
4. Right-click the LogOutputLevel value and click Modify.
5. Type the desired output level in the Value data box. (The default value data is 1 for errors.)
6. Click OK.
Restart the GO-Global Application Publishing Service.
|